(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter

Product Details
Clapboard: without Clapboard
Filter Number: 1
Medium Material: Synthetic Fiber
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
17000000 RMB
Plant Area
>2000 square meters
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
  • (H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
Find Similar Products

Basic Info.

Filtration Grade
HEPA Filter
Box Material
Plastic Sprayed Cold-Rolled Steel Plate
Filter Type
Gel Sealing HEPA Filter
Customization
Dimention/Mateial/Logo/Packing
Model
Gkf-15A
Transport Package
Carton Boxes
Specification
Please refer to product specification
Trademark
SNYLI
Origin
China
HS Code
8421999090
Production Capacity
400000 Sets /Year

Product Description

HEPA terminal HEPA filter box


Application:Mainly used in hospital operating rooms, laboratories or clean rooms in pharmaceutical factories.
Housing material: Powder Coated cold rolled steel sheets
Air inlet duct material:Powder Coated cold rolled steel sheets
Uniform flow orifice plate material:Powder Coated cold rolled steel sheets/Powder Coated cold rolled aluminium sheets/Stainless steel
(SUS304)
Briquetting material: Galvanized steel sheets
Heating insulation material:PE
Customized size: Available
HEPA filter:Mini pleat HEPA filter/Deep pleat HEPA filter /Top Gel sealing HEPA filter/Side Gel sealing HEPA filter

PRODUCT INTRODUCTION

* Two choices of mechanical sealing and liquid tank sealing, better sealing performance.
* Replaceable structure.
* Pre- installed testing port for easy filter testing
(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter
(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter

 

 
 
Model Air flow
(m³/h)
Top inlet duct type
Box dimension(mm)
Side inlet duct type
Box dimension(mm)
HEPA filter
Dimension (mm)
Inlet duct
Dimension (mm)
GKF-5A 500 465×465×280 465×465×450 400×400×95
(Top gel sealing )
200×200
GKF-10A 1000 615×615×280 615×615×450 550×550×95
(Top gel sealing)
200×320
GKF-15A 1500 695×695×280 695×695×450 630×630×95
(Top gel sealing)
250×320
GKF-20A 2000 675×980×280 675×980×450 610×915×95
(Top gel sealing)
250×500
GKF-5B 500 500×500×280 500×500×450 430×430×90
(Side gel sealing)
200×200
GKF-10B 1000 680×680×280 680×680×450 610×610×90
(Side gel sealing)
200×320
GKF-15B 1500 985×680×280 985×680×450 915×610×90
(Side gel sealing)
200×400
GKF-20B 2000 1290×680×280 1290×680×450 1220×610×90
(Side gel sealing)
200×500
GKF-30B 3000 1290×985×280 1290×985×450 1220×915×90
(Side gel sealing)
200×600

(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter(H14, H13) Gel Sealing HEPA Filter Box HEPA Air Supply Outlet Ceiling Air Filter

Q1.Are you a manufacture or trading company?
A:We are a manufacure.
Snyli Environmental Technology (Shandong) Co., Ltd was established in 2010, is a professional service provider of air purification products integrating R&D, production and sales, with registered brand- SYNLI.


Q2: Where are air filters commonly used?
A :HAVC(heating, air conditioning and ventilation systems) painting stations, chemical plants, pharmaceutical plants, cement or asphalt powder plants, clean rooms, power stations, heavy metal industries, gas turbines and cogeneration power plants, engineering and equipment plants, drying and baking rooms, hospitals, etc.

Q3: What are your testing criteria?
A: EN779:2012 ISO9001


Q4: What is the international standard for air filters?
A:Euro :Pre (G1-G4), Medium (F5-F9), HEPA (H10-H14) ULPA (U15-U17)
American :Pre (MERV5-7), Medium (MERV8-14), HEPA (MERV15-19) ULPA(MERV 20)


Q5: What is your sample policy?
A: The sample price will be the product price of the standard order. If you make a demo order after receiving the sample and proofing (reaching our MOQ), we will roughly understand the sample price and sample price in the order, and give us your MOQ price.

Q6: How about your after-sales service?
A: Even if we have confidence in the quality of our products, the products may be damaged due to some unpredictable reasons. Please use and maintain the products you purchased correctly in accordance with the user manual or the recommendations of the sales staff. Contact the household to understand the usage of the product, provide suggestions or support professional maintenance services according to the warranty policy.

 