People or goods enter the clean area by the fan through the air shower nozzle, which sprays the filtered clean strong wind to remove the dust that has adhered to the surface of people or objects. This is known as an air shower room (Dust Free Industrial Air Shower).
The Dust Free Industrial Air Shower is a piece of equipment that purifies the air before people enter a clean area or a clean workshop. It has strong versatility and can be used with any clean area or clean plant. Staff members must use this equipment to enter the workshop because it provides strong clean air and quickly and effectively removes dust, hair, hair dandruff, and other debris from clothing.
Specification
Model |
TYPE |
External dimension (W×D×H) (mm) |
Inner dimension (W×D×H) (mm) |
Shower time |
Nozzle Qty |
Power supply |
Power consumption |
SL-FL1100 |
1 man/
2-side blowing |
1100×720×2080 |
1200×1000×2100 |
0s ~99s (Ajustable)
*Factroy setting:10s |
7 |
380V
50HZ |
1500W |
SL-FL1200 |
1-2 man/
2-side blowing |
1200×1000×2100 |
800×900×1910 |
13 |
SL-FL1240S |
2-4 man/
2-side blowing |
1240×2000×2100 |
800×1900×1910 |
26 |
Control and maintenance
The purpose of environmental control and daily maintenance of clean room air shower room is to kill the bacterial propagules produced by the production process and control the microbial content in the clean room. These measures can only control the amount of bacteria and miscellaneous bacteria species in the clean room air, if there are more mold, we must first spray the room with 5% carbolic acid comprehensively, and then fumigate with formaldehyde to achieve the sterile effect, and only then can we kill bacteria and miscellaneous bacteria spores. At the end of each production cycle, the clean room with aseptic requirements is disinfected with disinfectant before the next cycle of production, and after testing the number of dust particles in the clean room meets the regulations, then the clean room is fumigated with formaldehyde gas, and from the results of long-term testing, this method of environmental sterilization is very effective.
Factors affecting the air of the air shower room
1. Operators in the clean room should work in strict accordance with the operation rules of the clean room. The doors and windows of the clean room should be closed at all times, and there should be a buffer zone between the clean room and the non-clean room for the transfer of people and goods, and there should be wind bath equipment to stop the convection of airflow, and people who have nothing to do with production cannot enter the clean room.
2,The number of air changes in the clean room and the air supply of the air conditioning purification system are the main internal factors to maintain the positive pressure and cleanliness of the clean room, but it is restricted by the final resistance of the filters at all levels in the purification system.
3,The equipment in the clean room requires regular, timed, and scheduled cleaning and maintenance, and whether the materials and cleaning liquids used in the cleaning are in accordance with the regulations of the clean room management, etc.